The Malyugin Ring

The Malyugin Ring
Soosan Jacob
Soosan Jacob
Published: Wednesday, May 1, 2013
Recognition of the intraoperative floppy iris syndrome (IFIS) by Chang and Campbell has allowed the surgeon to be forewarned in many cases regarding the possibility of intra-operative iris billowing, iris prolapse and progressive miosis. Of the many solutions available for tackling the small pupil secondary to IFIS and other causes, the Malyugin Ring (MicroSurgical Technology) has proven to be very popular. This is a transitory, square shaped implant, made of polypropylene with four circular scrolls that engage the pupillary margin at equidistant points providing a balanced stretch. It is implanted and explanted through an injector. Designed by Boris Malyugin MD (Cataract and Implant Surgery Department chief, deputy director (R&D, Edu) at the S. Fyodorov Eye Microsurgery Complex, Moscow), the Malyugin Ring has several advantages over traditional iris retractor hooks and other pupil dilating devices. Implantation and explantation are performed with an injector and are relatively simple. As the device is implanted through the main port, additional incisions are not required making the procedure less traumatic and easier. It can be inserted through regular incisions as well as through the 1.6-1.8mm microincisions used in MICS with a woundassisted technique of insertion and removal. The unique design of the device provides eight points of pupillary margin fixation equating it to eight iris hooks. It gives a uniform, gentle dilatation to the pupil with lack of excessive stress at localised points, resulting in a better postoperative appearance of the pupil. The ring has a reliable clamping mechanism keeping the position of the ring stable throughout the procedure. "The main concept of the ring is the paper clip iris margin fixation. The idea for this design did not come from the real paper clip but from the haptic design of the T-26 model IOL which has two closed-loop haptics made from polypropylene . Polypropylene is quite flexible as opposed to PMMA. To add some rigidity to the haptic, the loop at the centre of each haptic element was created. This IOL was the first IOL with yellow-tinted PMMA optics, that was designed back in the mid 90s. To date more than 1,000,000 of these lenses have been implanted in Russia and surrounding countries (ex-SU). In some cases, during implantation (positive pressure from the posterior segment, AC shallowing, etc), I experienced the problem of catching the anterior lens capsule and sometimes the iris. At some point of time, the idea of using this loop as a basis for the pupil expanding device occurred," says Dr Malyugin. How did this innovation happen? Dr Malyugin answered:"The leading driving force of innovation, at least in my case, was the necessity to solve the problem. Like all other innovations, time just came to the point when it was necessary to take the step forward. This was so with the wheel which was invented to solve the problem of high friction occurring with the sledge; and was so with oblique sails invented to increase manoeuvrability of the ships on the seas, enhancing ability to sail against the wind. There are also many other examples." The Malyugin Ring is manufactured in two sizes, 6.25mm and 7.0mm. The smaller one being universal for almost any case with small pupil. The larger one is useful in IFIS. It may also be preferred by surgeons using the phaco flip technique for nucleus as well as when implanting an IOL with 6.5mm optic. On surgical pointers in insertion and removal techniques, Dr Malyugin advises: "Before inserting the ring it is better not to overfill the anterior chamber with viscoelastic to avoid pushing the iris against the anterior lens capsule. If posterior synechiae exist, they should be lysed first. With very small pupils, it is advisable to enlarge it to 3-3.5mm by stretching with two instruments and then inject the ring. The injector should be placed at the centre of the anterior chamber and the ring is expelled from it by pressing on the thumb button. As soon as the distal scroll is engaged with the iris, I prefer to start retracting the inserter while simultaneously injecting the ring. "Before removing the ring I prefer to disengage both proximal and distal scrolls, leaving the two lateral scrolls in place. While engaging the proximal scroll (curl) with the inserter hook, the second instrument is introduced through the paracentesis to lift this scroll above the iris and help position it on the injector plate. I think there are no major problems in insertion and removal." The ring can also be used in cases with posterior capsular rupture without fear of dropping into the vitreous cavity by using the Agarwal modification proposed by Prof Amar Agarwal. "We tie a 6-0 polyglactin vicryl suture to the leading scroll of the ring before implantation to secure a hold on the ring throughout the surgery. This prevents the expander device from inadvertently dropping into the vitreous during intra-operative manipulation," says Prof Agarwal. Other advantages of the Malyugin Ring include lack of any sharp or pointed ends which can damage intraocular tissue, equidistant loops which give just the required dilatation without causing overstretching of the pupil, retention of iris tissue in the right plane without forward bunching thus giving adequate anterior chamber space for performing phaco manoeuvres and the balanced stretch and stabilisation of iris tissue provided in cases with IFIS.              
Tags: Boris-Malyugin, Soosan-Jacob
Latest Articles
Glaucoma Treatment Under Pressure

New techniques and technologies add to surgeons’ difficult decisions

Read more...

Outside the Box, Inside the Pipeline

Researchers are tackling glaucoma diagnosis and treatment from all sides.

Read more...

The EHDS Is Ready for the Green Light

If proposal is approved, Europe could see better access to, and exchange and use of, health data.

Read more...

ESCRS to Release Guidelines for Cataract and Refractive Surgery

Comprehensive approach to the safest and most effective modern surgery.

Read more...

Barry Fellowship Opens Up ‘Whole New Field of Thought’

The 2022 recipient combines theoretical and practical to learn new treatments.

Read more...

Digitalising the OR—Experience and Perspectives

Benefits include saving time and improving outcomes.

Read more...

ESCRS Heritage Programme

Visionaries past and present.

Read more...

Dynamic Measures Needed for Quality of Vision

Functional visual acuity testing and straylight metering may better reflect real-world conditions.

Read more...

What Is Stopping Digital OR Adoption?

Ophthalmologists know the benefits—now it’s time to construct the right plan.

Read more...

Time to Move Beyond Monofocal IOLs?

European surgeons appear hesitant to first offer other presbyopia-correcting options to patients.

Read more...

;